3-Line Filters for Converters and Power Electronics Power line filters for three-phase systems Rated voltage 500, 690 and 760 V~ Rated current 150 A to 2500 A Construction Three-line filter Metal case B84143-B*-S20 ... B84143-B*-S24 Features Low leakage current Easy to install Very compact design B84143-B150...B600-S20: UL, CUL approval B84143-B150...B600-S21/S24: UL, CUL approval for 600/350 V~ Optimized for operation under full load Low weight Applications B84143-***-S24 for IT mains supply Frequency converters for motor drives Wind farms Power supplies Terminals Busbars Marking Marking on component: Manufacturer's logo, ordering code, rated voltage, rated current, rated temperature, date code Minimum marking on packaging: Manufacturer's logo, ordering code Typical circuit diagram LINE L1 L2 L3 LOAD L1' L2' L3' SSB1212-L 255 03/01 3-Line Filters for Converters and Power Electronics Technical data Rated voltage V R B84143-B*-S20 ... B84143-B*-S24 500/290 V~, 50/60 Hz (type -S20) 690/400 V~, 50/60 Hz (type -S24); UL, CUL 600/350 V~ 760/440 V~, 50/60 Hz (type -S21);UL, CUL 600/350 V~ Referred to 40 C ambient temperature 2121 V-, 2 s (line/line) 2686 V-, 2 s (lines/case) type -S20 2890 V-, 2 s (lines/case) type -S21, -S24 1,5 * IR for 3 min per hour or 2,5 * IR for 30 s per hour at VR, 50 Hz 25/100/21 (- 25 C/+ 100 C/21 days damp heat test) in accordance with EN 60068-1 Rated current I R Test voltage VP Overload capability Leakage current I leak Climatic category Characteristics and ordering codes IR A 150 180 250 320 400 600 1000 1600 2500 I leak mA <6 <6 <6 <6 <6 <6 <6 <6 <6 Rtyp 140 140 63 67 67 52 33 22 15 Approx. weight kg 13 13 15 21 21 22 28 34 105 Ordering code B84143-B150-S** B84143-B180-S** B84143-B250-S** B84143-B320-S** B84143-B400-S** B84143-B600-S** B84143-B1000-S** B84143-B1600-S** B84143-B2500-S** Compilation of ordering code Replace the asterisks ** by the code number for the required version: 20 = 500 V 21 = 760 V 24 = 690 V (filter for IT mains supply. See also chapter "General, network types", page 51) 256 03/01 3-Line Filters for Converters and Power Electronics Dimensional drawings B84143-B150-S**, B84143-B180-S** 260 150 91 321 36 B84143-B*-S20 ... B84143-B*-S24 321 2 x M5 / 5 mm tief deep x M5 / 5 mm L1 1550,2 170 L3 L2 L3 L2 LINE LOAD 6,6 2 81 141 10 97,5 10 1150,2 97,5 3102 o9 PE M10 x 30 SSB1266-K B84143-B250-S** 300 2400,6 91 60 36 x M6 / 6 mm 2 x M6 / 6 mm tief deep 60 L1 L3 L2 LINE o12 LOAD L3 L2 2 421 3602 15 116 421 15 o11 PE M10 x 30 25 SSB1206-C 257 03/01 30 110 140 Marking L1 20 165 190 5 80 30 120 140 Marking L1 3 80 3-Line Filters for Converters and Power Electronics B84143-B320-S**, B84143-B400-S** 300 2401 91 60 36 B84143-B*-S20 ... B84143-B*-S24 60 4 x M6 / 6 mm 4 x M6 / 6 mm tief deep L1 L3 L3 LINE LOAD 422 15 o12 3602 422 15 2 16 850,5 116 o11 PE M10 x 30 25 SSB1207-K B84143-B600-S** 350 2901 91 60 36 4 x M6 / 6/ mm tief deep x M6 6 mm 60 L1 L3 L3 LINE LOAD o12 423 15 4102,5 423 15 2 16 850,5 116 o11 PE M10 x 30 30 SSB1208-T 258 03/01 30 1800,5 210 2351 260 Marking 5 L1 120 L2 L2 30 1800,5 210 2351 260 Marking 5 L1 120 L2 L2 3-Line Filters for Converters and Power Electronics B84143-B1000-S** 65 350 2901 141 65 61 B84143-B*-S20 ... B84143-B*-S24 4 M6 / 6 mm tief 4 xx M6 / 6 mm deep 8 L1 LINE L3 LOAD L3 o12 523 20 4202,5 523 20 2,5 16 1350,8 166 o14 PE M12 x 30 40 SSB1209-2 B84143-B1600-S** 400 3401 141 105 61 105 L1 10 LINE L3 LOAD L3 923 20 o14 o12 5503 923 20 2,5 16 1350,8 166 40 40 PE M12 x 30 SSB1210-5 259 03/01 50 40 2200,8 250 2751 300 Marking L2 L2 L1 160 40 2200,8 250 2751 300 Marking L2 L2 L1 160 4 x M6 / 6/mmmm deep x M6 6 tief 3-Line Filters for Converters and Power Electronics B84143-B2500-S** 650 5601,5 B84143-B*-S20 ... B84143-B*-S24 125 125 191,5 91,5 4 x M6 / 4 6 M6 / 6deep x mm tief L1 15 3551 385 LINE L3 LOAD L3 933 o14 8103,5 933 3,5 16,5 20 40 20 40 1901 221,5 o14 PE M16 x 50 40 80 SSB1211-D 260 03/01 60 2861 320 Marking L2 L2 L1 200 3-Line Filters for Converters and Power Electronics Insertion loss (typical values at Z = 50 ) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) B84143-B150-S20, B84143-B180-S20 100 SSB1267-T B84143-B*-S20 ... B84143-B*-S24 B84143-B250-S20 100 dB SSB1799-S e dB 80 e 80 60 60 40 40 20 20 0 10 4 10 5 10 6 10 7 Hz 10 8 f 0 10 4 10 5 10 6 10 7 f Hz 10 8 B84143-B320-S20 ... B84143-B2500-S20 100 dB SSB1800-Z e 80 60 40 20 0 10 4 10 5 10 6 10 7 f Hz 10 8 261 03/01 3-Line Filters for Converters and Power Electronics Insertion loss (typical values at Z = 50 ) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) B84143-B150-S21, B84143-B250-S21 100 SSB1267-T B84143-B*-S20 ... B84143-B*-S24 B84143-B320-S21 ... B84143-B2500-S21 100 SSB1204-V e dB 80 e dB 80 60 60 40 40 20 20 0 10 4 10 5 10 6 10 7 Hz 10 8 f 0 10 4 10 5 10 6 10 7 Hz 10 8 f B84143-B150-S24, B84143-B250-S24 100 SSB1268-2 B84143-B320-S24 ... B84143-B2500-S24 100 dB SSB1801-8 e dB 80 e 80 60 60 40 40 20 20 0 10 4 10 5 10 6 10 7 Hz 10 8 f 0 10 4 10 5 10 6 10 7 f Hz 10 8 262 03/01 Herausgegeben von EPCOS AG Marketing Kommunikation, Postfach 80 17 09, 81617 Munchen, DEUTSCHLAND ++49 89 636 09, FAX (0 89) 636-2 26 89 EPCOS AG 2000. Alle Rechte vorbehalten. Vervielfaltigung, Veroffentlichung, Verbreitung und Verwertung dieser Broschure und ihres Inhalts ohne ausdruckliche Genehmigung der EPCOS AG nicht gestattet. Mit den Angaben in dieser Broschure werden die Bauelemente spezifiziert, keine Eigenschaften zugesichert. Bestellungen unterliegen den vom ZVEI empfohlenen Allgemeinen Lieferbedingungen fur Erzeugnisse und Leistungen der Elektroindustrie, soweit nichts anderes vereinbart wird. Diese Broschure ersetzt die vorige Ausgabe. Fragen uber Technik, Preise und Liefermoglichkeiten richten Sie bitte an den Ihnen nachstgelegenen Vertrieb der EPCOS AG oder an unsere Vertriebsgesellschaften im Ausland. Bauelemente konnen aufgrund technischer Erfordernisse Gefahrstoffe enthalten. Auskunfte daruber bitten wir unter Angabe des betreffenden Typs ebenfalls uber die zustandige Vertriebsgesellschaft einzuholen. Published by EPCOS AG Marketing Communications, P.O. Box 80 17 09, 81617 Munich, GERMANY ++49 89 636 09, FAX (0 89) 636-2 26 89 EPCOS AG 2000. All Rights Reserved. Reproduction, publication and dissemination of this brochure and the information contained therein without EPCOS' prior express consent is prohibited. The information contained in this brochure describes the type of component and shall not be considered as guaranteed characteristics. Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry recommended by the ZVEI (German Electrical and Electronic Manufacturers' Association), unless otherwise agreed. This brochure replaces the previous edition. For questions on technology, prices and delivery please contact the Sales Offices of EPCOS AG or the international Representatives. Due to technical requirements components may contain dangerous substances. For information on the type in question please also contact one of our Sales Offices. 1 |
Price & Availability of B84143-B600-S24 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |